19:06, 30 April 2005 . .
en:User:Ali@gwc.org.uk (Talk) . . 700x762 (57531 bytes) (photograph of mechanism of an electrical induction meter (kilo-watt hour meter) Image taken by me Ali@gwc.org.uk 19:06, 30 Apr 2005 (UTC)
DescriptionElectricityMeterMechanism.jpg
English: mechanism of electromechanical induction meter in UK.
Voltage coil - many turns of fine wire encased in plastic, connected in parallel with load.
Current coil - three turns of thick wire, connected in series with load.
Stator - concentrates and confines magnetic field.
Aluminium rotor disc.
rotor brake magnets.
spindle with worm gear.
display dials - note that the 1/10, 10 and 1000 dials rotate clockwise while the 1, 100 and 10000 dials rotate counter-clockwise.
to share – to copy, distribute and transmit the work
to remix – to adapt the work
Under the following conditions:
attribution – You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.
share alike – If you remix, transform, or build upon the material, you must distribute your contributions under the
same or compatible license as the original.
Moved from en-wiki, original image: http://en.wikipedia.org/wiki/Image:ElectricityMeterMechanism.jpg 19:06, 30 April 2005 . . Ali@gwc.org.uk (Talk) . . 700x762 (57531 bytes) (photograph of mechanism of an electrical induction meter (kilo-watt hour meter)